- 23 -
Special Function
Group
A6 type A5 HOLD function Set value lock
See (Table 5-4). : OFF : Unlock
: ON : Lock 1
A1 Energized/De-energized : Lock 2
: Energized A6 HOLD function
: De-energized : OFF Input sampling period
: ON : 25 ms
A2 Energized/De-energized : 125 ms
: Energized A1 hysteresis : 250 ms
: De-energized 0.1 to 100.0 ( )
Auto-light function
A3 Energized/De-energized A2 hysteresis : Disabled
: Energized 0.1 to 100.0 ( ) : Enabled
: De-energized
A3 hysteresis Display selection
A4 Energized/De-energized 0.1 to 100.0 ( ) :
: Energized Input value/A1 value
: De-energized A4 hysteresis : Input value
0.1 to 100.0 ( ) : A1 value
A5 Energized/De-energized : No indication
: Energized A5 hysteresis
: De-energized 0.1 to 100.0 ( ) Indication time
00.00 to 60.00 (Min.Sec)
A6 Energized/De-energized A6 hysteresis
: Energized 0.1 to 100.0 ( )
: De-energized
A1 delay time
A1 HOLD function 0 to 9999 sec
: OFF
: ON A2 delay time
0 to 9999 sec
A2 HOLD function
: OFF A3 delay time
: ON 0 to 9999 sec
A3 HOLD function A4 delay time
: OFF 0 to 9999 sec
: ON
A5 delay time
A4 HOLD function 0 to 9999 sec
: OFF
: ON A6 delay time
0 to 9999 sec